clear lacquer micro flowmeter
email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD mainly produces super mirco flow meter,oval gear flowmeter ,coriolis mass flow meter,electromagnetic flow meter,piston flow meter,spurgear flow meter,gear pump,gear metering pump. We use high accurate CNCmachining center to make sure the high quality of our instruments and thecutting accuracy is 0.0001mm and has reached the world leading level. Forexample, the flow meter LSF40 of Japan OVAL, the flow range is 0.7~50L/H, butour CX-M5-AL is 0.3~60L/H with accuracy 0.5%F.S. We have applied many materialinto use on our flow meter,such as aluminium oxide, SS316L, PEEK,Ti ande soon.for different application and liquids.

clear lacquer micro flowmeter
At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.
SinceMay 23, 2011, Shanghai Jinshen Instrument Co., Ltd. successfully released a newoval gear flow meter CX-M and G series, the liquid flowmeter range than thefirst in China reached more than 1: 100, and at the same time to ensureaccuracy 0.5% above the flowmeter industry model.From this since the base meterhas been a pioneer in flowmeter technology, but also one of the high-endflowmeter brand.The perfect technical level, excellent quality standards,innovation has been innovation Wells said. Deep base flow meter has been toprovide customers with a reliable use of the experience in the past rely on theimport of the era, the customer has been a headache for after-sales service,and base deep flow meter with 8 years of use of the long life, in one fellswoop cracked this situation.

clear lacquer micro flowmeter
Componentsand principles of the Oval gear flow meter - The measurement part of the flowmeter consists of two intermeshing gears and its housing (metering chamber).The measured medium mass per revolution of the gear is half-moon-shaped 4times, in the mirco flow meter hemispherical volume under certain conditions,as long as the measured gear rotation speed n, we can know the measured mediumflow.

clear lacquer micro flowmeter
Item | model | K-factor | The minimum flow | Flow range | Connection size |
Gear flow meter | CX-G0.025-P-AL | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.025-P-SS | 0.025ml | 0.001L/Min | 0.004~1 L/min | G1/8 |
gear flow meter | CX-G0.04-P-AL | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.04-P-SS | 0.04ml | 0.004L/min | 0.01~2L/min | G1/4 |
gear flow meter | CX-G0.1-P-AL | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.1-P-SS | 0.1ml | 0.008L/min | 0.02~4L/min | G3/8 |
gear flow meter | CX-G0.2-P-AL | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.2-P-SS | 0.245ml | 0.01L/Min | 0.08~8L/min | G3/8 |
gear flow meter | CX-G0.4-P-AL | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G0.4-P-SS | 0.4ml | 0.01L/Min | 0.1~20L/min | G1/2 |
gear flow meter | CX-G1-P-AL | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G1-P-SS | 1ml | 0.02L/Min | 0.2~40L/min | G1/2 |
gear flow meter | CX-G2-P-AL | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
gear flow meter | CX-G2-P-SS | 2ml | 0.04L/Min | 0.5-60L/min | G3/4 |
Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized
Commonfault causes, troubleshooting
a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.
b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.
c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.
d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.